Abstract

Objective: To evaluate the morphometric parameters of the C2 (axis) lamina related to the intralaminar fixation technique and compare the dimensions between sexes.

Methods: Descriptive anatomical study of 59 C2 vertebrae from cadavers (30 male and 29 female). Seven morphometric parameters were bilaterally measured by four independent examiners using a standard analog caliper. Statistical analysis included normality tests, t-Student, Mann-Whitney, and Kruskal-Wallis.

Results: Morphometric measurements showed significant differences between sexes, with greater values in males (p<0.05). Lamina thickness was less than 4 mm in 25.20% of cases, more frequently in females.

Conclusions: Intralaminar fixation of the axis must account for anatomical variations, particularly in females. Lamina thickness below 4 mm limits the safe use of 3.5 mm screws, emphasizing the need for detailed preoperative assessment. Level of Evidence IV; Descriptive Anatomical Observational Study.

Keywords

Anatomy; Axis; Cervical Vertebra; Bone Fixation; Spine; Anthropometry. 

Resumo

Objetivo: Avaliar os parâmetros morfométricos da lâmina da vértebra C2 (áxis) relacionados à técnica de fixação intralaminar e comparar as dimensões entre os sexos.

Métodos: Estudo anatômico descritivo realizado com 59 vértebras C2 provenientes de cadáveres (30 masculinos e 29 femininos). Sete parâmetros morfométricos foram mensurados bilateralmente por quatro avaliadores utilizando paquímetro analógico. Análises estatísticas incluíram testes de normalidade, t-Student, Mann-Whitney e Kruskal-Wallis.

Resultados: As medidas morfométricas apresentaram variações significativas entre os sexos, sendo maiores no sexo masculino (p<0,05). A espessura da lâmina foi inferior a 4 mm em 25,20% dos casos, sendo mais frequente em mulheres.

Conclusões: A técnica de fixação intralaminar do áxis deve considerar as variações anatômicas, especialmente em mulheres. A espessura inferior a 4 mm limita o uso seguro de parafusos de 3,5 mm, reforçando a necessidade de avaliação pré-operatória detalhada. Nível de Evidência IV; Estudo Observacional Descritivo Anatômico.

Palavras-chave

Anatomia; Vértebra Cervical Áxis; Fixação Óssea; Coluna Vertebral; Antropometria. 

Resumen

Objetivo: Evaluar los parámetros morfométricos de la lámina de la vértebra C2 (axis) relacionados con la técnica de fijación intralaminar y comparar las dimensiones entre sexos.

Métodos: Estudio anatómico descriptivo con 59 vértebras C2 de cadáveres (30 masculinas y 29 femeninas). Siete parámetros morfométricos fueron medidos bilateralmente por cuatro evaluadores utilizando calibrador analógico. Se aplicaron pruebas de normalidad, t-Student, Mann-Whitney y Kruskal-Wallis.

Resultados: Las medidas morfométricas mostraron diferencias significativas entre sexos, siendo mayores en los hombres (p<0,05). El grosor de la lámina fue inferior a 4 mm en el 25,20% de los casos, con mayor frecuencia en mujeres.

Conclusiones: La fijación intralaminar del axis debe considerar variaciones anatómicas, especialmente en mujeres. Un grosor inferior a 4 mm limita el uso seguro de tornillos de 3,5 mm, destacando la importancia de la evaluación preoperatoria. Nivel de Evidencia IV; Estudio Observacional Anatómico Descriptivo.

Palabras clave

Anatomía; Vértebra Cervical Axis; Fijación de Fractura; Columna Vertebral; Antropometría.

Referências

1 Magerl F, Seemann PS. Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A. Cervical spine I. Wien: Springer: 1987.p.322-327.

2 Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976). 2001;26(22):2467-71. doi: 10.1097/00007632-200111150-00014.

3 Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech. 2004;17(2):158-62. doi: 10.1097/00024720-200404000-00014

4 Jea A, Sheth RN, Vanni S, Green BA, Levi AD. Modification of Wright’s technique for placement of bilateral crossing C2 translaminar screws: technical note. Spine J. 2008;8(4):656-60. doi: 10.1016/j.spinee.2007.06.008.

5 Singh DK, Shankar D, Singh N, Singh RK, Chand VK. C2 Screw fixation techniques in atlantoaxial instability: A technical review. J Craniovertebr Junction Spine. 2022;13(4):368-377. doi: 10.4103/jcvjs.jcvjs_128_22.

6 Chan AKH, Yusof MI, Abdullah MS. Computed Tomographic Morphometric Analysis of C1 and C2 for Lamina Cross Screw Placement in Malay Ethnicity. Asian Spine J. 2021;15(1):1-8. doi: 10.31616/asj.2019.0242.

7 Joaquim AF, Tan L, Riew KD. Posterior screw fixation in the subaxial cervical spine: a technique and literature review. J Spine Surg. 2020;6(1):252-261. doi: 10.21037/jss.2019.09.28.

8 Sharma RM, Pruthi N, Pandey P, Dawn R, Ravindranath Y, Ravindranath R. Morphometric and radiological assessments of dimensions of Axis in dry vertebrae: A study in Indian population. Indian J Orthop. 2015;49(6):583-8. doi: 10.4103/0019-5413.168758.

9 Zhou LP, Shang J, Zhang ZG, Jiang ZF, Zhang HQ, Jia CY, et al. Characteristics and Comparisons of Morphometric Measurements and Computed Tomography Hounsfield Unit Values of C2 Laminae for Translaminar Screw Placement Between Patients With and Without Basilar Invagination. Neurospine. 2022;19(4):899-911. doi: 10.14245/ns.2244730.365.

10 Nassos JT, Ghanayem AJ, Sasso RC, Tzermiadianos MN, Voronov LI, Havey RM, et al. Biomechanical evaluation of segmental occipitoatlantoaxial stabilization techniques. Spine (Phila Pa 1976). 2009;34(25):2740-4. doi: 10.1097/BRS.0b013e3181b61185.

11 Moon BJ, Choi KH, Shin DA, Yi S, Kim KN, Yoon DH, et al. Anatomical variations of vertebral artery and C2 isthmus in atlanto-axial fusion: Consecutive surgical 100 cases. J Clin Neurosci. 2018;53:147-152. doi: 10.1016/j.jocn.2018.04.058.

12 Lin S, Bao M, Wang Z, Zou X, Ge S, Ma X, et al. Morphological Evaluation of the Subaxial Cervical Spine in Patients with Basilar Invagination: A CT-based Study. Spine (Phila Pa 1976). 2021;46(20):1387-1393. doi: 10.1097/BRS.0000000000004040.

13 Ma XY, Yin QS, Wu ZH, Xia H, Riew KD, Liu JF. C2 anatomy and dimensions relative to translaminar screw placement in an Asian population. Spine (Phila Pa 1976). 2010;35(6):704-8. doi: 10.1097/BRS.0b013e3181bb8831.

14 Chan AKH, Yusof MI, Abdullah MS. Computed Tomographic Morphometric Analysis of C1 and C2 for Lamina Cross Screw Placement in Malay Ethnicity. Asian Spine J. 2021;15(1):1-8. doi: 10.31616/asj.2019.0242.

15 Vaccaro A, Baron EM. Operative techniques in spine surgery. 4th edition. Philadelphia: Elsevier;2025.p.72.

16 Cassinelli EH, Lee M, Skalak A, Ahn NU, Wright NM. Anatomic considerations for the placement of C2 laminar screws. Spine (Phila Pa 1976). 2006;31(24):2767-71. doi: 10.1097/01.brs.0000245869.85276.f4.

17 Dorward IG, Wright NM. Seven years of experience with C2 translaminar screw fixation: clinical series and review of the literature. Neurosurgery. 2011;68(6):1491-9; discussion 1499. doi: 10.1227/NEU.0b013e318212a4d7.
 


Submetido em:
09/11/2024

Aceito em:
30/03/2025

6a909d4ea953952ca01592a7 coluna Articles
Links & Downloads

Coluna/Columna

Share this page
Page Sections