Morfometria dos pedículos de C7 avaliados por tomografia computadorizada axial
Morphometric evaluation of C7 pedicles by axial computed tomography
Morfometría de los pedículos de C7 evaluados por tomografía computarizada axial
William Gemio Jacobsen Teixeira, Henrique Mennucci de Haidar Jorge, Thiago Pasqualin, Alexandre Sadao Iutaka, Marcelo Bordalo Rodrigues, Reginaldo Perilo Oliveira, Tarcísio Eloy Pessoa de Barros Filho
Coluna/Columna, vol.7, n3, p.185-190, 2008
Downloads: 0
Views: 4
Resumo
Objetivo: caracterizar as dimensões lineares e angulares do pedículo de C7 para determinar os parâmetros de segurança e melhorar o planejamento do procedimento cirúrgico. Métodos: foram avaliadas 100 tomografias computadorizadas cervicais consecutivas, com cortes axiais que demonstravam as maiores dimensões do pedículo de C7. Foram excluídos os pacientes com anormalidades anatômicas cervicais ou idade inferior à 18 anos. As medições realizadas foram as seguintes: diâmetro interno do pedículo (DIP), espessura da cortical interna (ECI) e espessura da cortical externa (ECE), diâmetro externo do pedículo (DEP), angulação do pedículo (APED) no plano axial e angulações mínima (AMIN) e máxima (AMAX) aceitáveis para a passagem de um parafuso de 3,5 mm de diâmetro. Resultados: a média de idade dos pacientes era de 52,99 anos, sendo 64 do sexo masculino e 36 do sexo feminino. A DEP média foi de 6,2 mm (4-8,3 mm), sendo maior em pacientes do sexo masculino. A DIP média foi de 4,01 mm (1,8-6 mm), sendo maior nos pacientes do sexo masculino. A ECI média foi de 1,32 mm (0,7-1,9 mm), sendo superior à ECE média, correspondendo a 0,87 mm (0,4-1,6 mm). A APED média foi de 41,21º (24º-57,7º). A AMAX média foi de 59,71º (43,7-78,4º) e a AMIN média de 18,53º (3,3-35º). Conclusões: a fixação transpedicular em C7 poderia ser realizada em todos os pacientes estudados. A ampla variação das medidas lineares e angulares reforça a necessidade da avaliação tomográfica pré-operatória dos casos que envolvem a fixação transpedicular de C7.
Palavras-chave
Coluna vertebral/anatomia & histologia; Tomografia computadorizada por raios-X; Fusão vertebral; Procedimentos ortopédicos/métodos
Abstract
Objective: to evaluate the linear and angular measurements of the C7 pedicle in order to determine the safety parameters and improve surgical planning. Methods: one-hundred consecutive cervical computed tomographies were evaluated. Axial tomographic images that showed the largest dimensions of C7 pedicle were utilized for this study. Patients that had cervical abnormalities and those below 18 years of age were excluded. The inner pedicle width (DIP), the internal cortical thickness (ECI), the outer cortical thickness (ECE), the external pedicle width (DEP), the pedicle angulation (APED) and the minimal (AMIN) and maximal (AMAX) acceptable angulation for a 3.5 mm diameter screw placement were measured. Results: the mean age was 52.99 years. Sixty-four patients were male and 36 female. The mean DEP was 6.2 mm (4-8.3 mm) and it was greater in males. The mean DIP was 4.01 mm (1.8-6 mm) and it was greater in males. The mean ECI was 1.32 mm (0.7-1.9 mm) and it was greater than the mean ECE, which was 0.87 mm (0.4-1.6 mm). The mean APED was 41.21º (24º-57.7º). The mean AMAX was 59.71º (43.7-78.4º) and the mean AMIN was 18.53º (3.3-35º). Conclusion: transpedicular screw placement in C7 pedicle could be done in all studied patients. The wide variability of linear and angular measurements reinforces the need of preoperative computed tomographic evaluation of all patients that will be submitted to a transpedicular C7 screw placement.
Keywords
Spine/anatomy & histology; Tomography, X-ray computed; Spinal fusion, Orthopedic procedures/methods
Resumen
Objetivo: Caracterizar las dimensiones lineares y angulares del pedículo de C7 para determinar los parámetros de seguridad y mejorar el planeamiento del procedimiento quirúrgico. Métodos: fueron evaluadas 100 tomografías computarizadas cervicales consecutivas. Fueron utilizados los cortes axiales que demostraron las mayores dimensiones del pedículo de C7. Fueron excluidos los pacientes con anormalidades anatómicas cervicales o edad inferior a los 18 años. Fueron medidos el parámetro interno del pedículo (DIP), el espesor de la cortical interna (ECI) y el espesor de la cortical externa (ECE), el diámetro externo del pedículo (DEP), la angulación del pedículo (APED) en el plano axial y las angulaciones mínima (AMIN) y máxima (AMAX) aceptables para la introducción de un tornillo de 3.5mm de diámetro. Resultados: el promedio de edad fue de 52.99 años. Fueron 64 pacientes del sexo masculino y 36 del sexo femenino. El DEP promedio fue de 6.2 mm (4-8.3mm) y fue mayor en el sexo masculino. El DIP promedio fue de 4.01mm (1.8-6mm) y fue mayor en el sexo masculino. El ECI promedio fue de 1.32mm (0.7-1.9 mm) y fue superior al promedio del ECE, que fue de 0.87mm (0.4-1.6mm). La APED promedio fue de 41.21(24º-57.7º). La AMAX promedio fue de 59.71º (43.7-78.4º) y la AMIN promedio de 18.53º (3.3-35º). Conclusiones: la fijación transpedicular en C7 podría ser realizada en todos los pacientes estudiados. La amplia variación de las medidas lineares y angulares refuerza la necesidad de la evaluación topográfica preoperatorio de los casos que involucran la fijación transpedicular de C7.
Palabras clave
Columna vertebral/anatomía & histología; Tomografía computadorizada por rayos X; Fusión vertebral; Procedimientos ortopédicos/métodos
Submetido em:
19/06/2008
Aceito em:
28/08/2008
