Avaliação tomográfica dos parafusos pediculares torácicos nas escolioses idiopáticas
Computed tomographic evaluation of thoracic pedicle screw placement in idiopathic scoliosis
Evaluación por tomografía de los tornillos pediculares torácicos en las escoliosis idiopáticas
Luciano Miller Reis Rodrigues, Rodrigo Junqueira Nicolau, Eduardo Barros Puertas, Marcelo Wajchenberg
Coluna/Columna, vol.7, n2, p.139-142, 2008
Downloads: 0
Views: 5
Resumo
Objetivo: estudo restrospectivo da acurácia da inserção dos parafusos torácicos na correção cirúrgica das escolioses idiopáticas, avaliando seu posicionamento, determinando a eficácia da técnica empregada e os riscos da sua colocação. Métodos: foram estudados 19 pacientes operados com o diagnóstico de escoliose idiopática no período de Maio de 2003 a Novembro de 2005. A média do valor angular das curvas foi de 67 graus, com a colocação de parafusos pediculares e ganchos na coluna torácica. Foram avaliados 78 parafusos pediculares por meio de tomografias computadorizadas (TC) com janela óssea, para verificar o posicionamento dos parafusos pediculares inseridos a mão livre, sem auxílio de navegação. Resultados: a média de correção das curvas no pós-operatório foi de 29º. O posicionamento correto dos parafusos na região central do pedículo foi de 76,92%, sendo que 21 parafusos ultrapassaram entre 2mm a 4mm a cortical pedicular (três mediais e 18 laterais). Houve quebra de dois dos parafusos. Foi identificado um caso de alteração neurológica no pós-operatório imediato, situação revertida totalmente após a remoção do parafuso que se encontrava a mais de 4mm medial ao centro do pedículo. Conclusões: a maioria dos parafusos avaliados estava inserida entre as corticais do pedículo, sem o auxílio de guias ou navegadores, podendo ser considerada uma técnica segura. Os parafusos mal posicionados estavam desviados lateralmente com maior freqüência.
Palavras-chave
Parafusos ósseos; Escoliose/cirurgia; Tomografia computadorizada por raios-X
Abstract
Objective: a retrospective observational study to determine the accuracy of transpedicular thoracic screws used in idiopathic scoliosis, evaluating the position and safety of the implants using postoperative computed tomography. Methods: twenty-nine patients that underwent scoliosis surgery between May 2003 and November 2005 were included in this study. The mean curves were 67 degrees, all patients had thoracic screws or hooks implanted. Seventy-eight pedicle screws were assessed by computed tomography to evaluate its position, after free handed technique. Results: the mean curves after surgery were 29 degrees. Seventy-six percent were fully contained into pedicle. Twenty-one screws were considered to have a breach between 2 and 4mm (3 medial, 18 lateral). Two screws were broken. One case of neurologic deficit was identified just after surgery that was completely recovered after screw removal. This screw had more than 4mm medial breach. Conclusions: Most screws were inserted between corticals. Free hand thoracic pedicle screw insertion technique appears to be safer. Misplaced screws were commonly inserted with lateral cortical perforation.
Keywords
Bone screws; Scoliosis/surgery; Tomography, X-ray computed
Resumen
Objetivo: realizar un estudio retrospectivo sobre el cuidado de la inserción de los tornillos torácicos en la corrección quirúrgica de las escoliosis idiopáticas, evaluando su posicionamiento, determinando la eficacia de la técnica empleada y los riesgos en su colocación. Métodos: fueron incluidos en el estudio diecinueve pacientes operados de escoliosis idiopática en el periodo de Mayo de 2003 a Noviembre de 2005. El promedio de las curvas fue de 67 grados, con colocación de tornillos pediculares y ganchos en la columna torácica. Fueron evaluados 78 tornillos pediculares por medio de tomografías computadorizadas (TC) con ventana ósea, para verificar el posicionamiento de los tornillos pediculares inseridos a mano libre, sin auxilio de navegación. Resultados: el promedio de corrección de las curvas en el post operatorio fue de 29º. El posicionamiento correcto de los tornillos en la región central del pedículo fue de 76.92%. Veinte un tornillos ultrapasaron entre 2mm a 4mm la corteza pedicular (3 mediales y 18 laterales). Hubo quiebra de 2 de los tornillos. Fue identificado un caso de alteración neurológica en el post operatorio inmediato, revertida totalmente después de la remoción del tornillo que se encontraba mas de 4mm medial al centro del pedículo. Conclusiones: la tomografía computadorizada permite evaluar el posicionamiento de los tornillos en la columna torácica en pacientes con escoliosis idiopática. La mayoría de los tornillos fueron inseridos entre las cortezas del pedículo, sin auxilio de guías o navegantes pudiendo ser considerado una técnica segura. Los tornillos mal posicionados fueron mas comúnmente desviados lateralmente.
Palabras clave
Tornillos óseos; Escoliosis/cirurgía; Tomografía computarizada por rayos-X
Submetido em:
04/03/2007
Aceito em:
29/07/2007