Estudo biomecânico comparativo da resistência às forças de compressão entre os parafusos pediculares poliaxiais e monoaxiais

Biomechanical comparative study of compression strength between poliaxial and monoaxial screws

Estudio biomecánico comparativo de la resistencia a fuerzas de compresión entre los tornillos pediculares poliaxiales y monoaxiales

Luiz Cláudio de Moura França, Mauricio Pagy de Calais Oliveira, Roberto Sakamoto Falcon, Manuel Araújo Porto Filho, Marcelo Gonçalves Rugani, Pablo Marriot Werlang, Leonardo Fernandes de Águiar, Roberto Zambelli de Almeida Pinto

Downloads: 0
Views: 7

Resumo

Objetivo: comparar a rigidez de um sistema de fixação pedicular composto por parafusos pediculares monoaxiais com outro composto por parafusos poliaxiais, submetidos às forças de compressão. Métodos: foi utilizado um modelo experimental para avaliar os sistemas de fixação montado e testado conforme as normas do padrão descrito pela American Society for Testing Materials (ASTM) no ensaio F1717-04. As amostras foram divididas em dois grupos, sendo o Grupo 1 composto pelos ensaios com parafusos fixos e o Grupo 2, com parafusos poliaxiais. Os componentes metálicos implantados foram produzidos com titânio de mesma origem. Os grupos experimentais foram submetidos a testes mecânicos na máquina universal de ensaios EMIC, modelo EMIC DL 1000. Resultados: os resultados obtidos no ensaio de compressão nas amostras do Grupo 1 tiveram carga máxima média de 2104,15 N e carga de escoamento média de 1822,55 N. Os resultados obtidos no ensaio de compressão nas amostras do Grupo 2 tiveram uma carga máxima média de 967,17 N e uma carga de escoamento média de 804,71 N. Visto terem sido realizados testes in vitro, os resultados devem ser analisados no contexto de que existem características cirúrgicas de adaptação da interface haste-parafuso que não são reproduzíveis no momento cirúrgico, quando comparados a testes realizados em condições ideais. Conclusão: o sistema de parafusos fixos apresentou maior resistência às forças de compressão quando comparado ao sistema com parafusos poliaxiais.

Palavras-chave

Parafusos ósseos; Placas ósseas; Fixação interna de fratura/instrumentação

Abstract

Objective: to compare rigidity of a pedicle fixation system composed of monoaxial pedicle screws to one composed of polyaxial screws, submitted to compression strengths. Methods: it has been used an experimental model to evaluate the fixation systems constructed and tested according to norms of the standard described by the American Society for Testing Materials (ASTM) in trial F1717-04. The samples were divided into two groups. Group 1 was composed of trials using fix screws; Group 2 used polyaxial screws. The metallic components implanted were produced with titanium coming from the same origin. The experimental groups were submitted to mechanical tests in a universal testing machine EMIC, model EMIC DL 1000. The results obtained in the compression trial in samples of Group 1 showed an average maximum charge of 2104.15 N, and an average discharging load of 1822.55 N. Results: the results obtained in the compression trial in the samples of Group 2 showed an average maximum charge of 967.17 N, and an average discharging load of 804.71 N. As the trials were in vitro, the results should be analyzed in the context that there are surgical characteristics of adaptation of the stalk/screw interface that are not reproducible in the surgical situation, when compared to tests carried out in ideal conditions. Conclusion: the system of fix screws has presented greater resistance to compression strengths as compared to the system with polyaxial screws.

Keywords

Bone screws; Bone plates; Fracture fixation, internal/instrumentation

Resumen

Objetivo: comparar la rigidez de un sistema de fijación pedicular compuesto por tornillos poliaxiales sometidos a las fuerzas de compresión. Métodos: Fue utilizado un modelo experimental para evaluar los sistemas de fijación montados y testados de acuerdo con las normas del patrón descrito por “American Society for Testing Materials” (ASTM) en el ensayo F1717-04. Las muestras fueron divididas en dos grupos, siendo el Grupo 1 compuesto por ensayos con tornillos fijos y el Grupo 2, con tornillos poliaxiales. Los componentes metálicos implantados fueron producidos con titanio del mismo origen. Los grupos experimentales fueron sometidos a testes mecánicos en la máquina universal de ensayos EMIC, modelo EMIC DL 1000. Resultados: los resultados obtenidos en el ensayo de compresión en las muestras del Grupo 1 tuvieron una carga máxima en promedio de 2104.15 N y una carga de declive en promedio de 1822.55 N. Los resultados obtenidos en el ensayo de compresión en las muestras del Grupo 2 tuvieron una carga máxima en promedio de 967.17 N y una carga de declive en promedio de 804.71 N. Como los testes fueron in vitro, los resultados deben ser analizados en el contexto de que existen características quirúrgicas de adaptación de la interfase hasta-tornillo que no son reproducibles en el momento quirúrgico, cuando comparados con los testes realizados en condiciones ideales. Conclusión: El sistema de tornillos fijos presentó mayor resistencia a las fuerzas de compresión cuando comparado con el sistema de tornillos poliaxiales.

Palabras clave

Tornillos óseos; Placas óseas; Fijación interna de fracturas/instrumentación